Lucene search
+L
SiemensSimatic Wincc (tia Portal)

14 matches found

CVE
CVE
added 2019/05/14 7:54 p.m.102 views

CVE-2019-10916

CVE-2019-10916 affects Siemens SIMATIC PCS7 and WinCC/TIA Portal products (multiple versions). The root cause is SQL Injection in the project file handling, allowing an attacker who can access the project file to run arbitrary commands with the local database server’s privileges, impacting confid...

9CVSS8.3AI score0.01541EPSS
Save
CVE
CVE
added 2019/05/14 7:54 p.m.95 views

CVE-2019-6576

CVE-2019-6576 affects Siemens SIMATIC HMI Comfort Panels (4"–22"), Comfort Outdoor Panels (7"/15"), KTP Mobile Panels (KTP400F, KTP700, KTP700F, KTP900, KTP900F), WinCC Runtime Advanced/Professional, WinCC (TIA Portal) and HMI Classic Devices (all versions prior to V15.1 Update 1). Root cause: in...

7.5CVSS7.2AI score0.01749EPSS
Save
CVE
CVE
added 2017/05/11 10:00 a.m.93 views

CVE-2017-6865

CVE-2017-6865 is a DoS vulnerability in Siemens PROFINET DCP handling affecting multiple Siemens products (WinCC, STEP 7/TIA Portal, PCS 7, WinAC/WinCC flexible, SCT, SINEMA, SINUMERIK, etc.). The root cause is improper input validation, where specially crafted PROFINET DCP broadcast packets on a...

6.5CVSS6AI score0.00469EPSS
Save
CVE
CVE
added 2019/05/14 7:54 p.m.91 views

CVE-2019-6577

CVE-2019-6577 is an XSS vulnerability in Siemens SIMATIC HMI/WinCC products (Comfort Panels, Outdoor Panels, KTP Mobile Panels, WinCC Runtime/Pro, WinCC in TIAPortal, and HMI Classic devices) exploitable via the integrated web server when an attacker can modify device configuration through SNMP. ...

5.4CVSS5.1AI score0.00876EPSS
Save
CVE
CVE
added 2019/05/14 7:54 p.m.89 views

CVE-2019-10918

Siemens CVE-2019-10918 affects multiple SIMATIC/WinCC products (e.g., WinCC/TIA Portal v14 with SP1 Upd 9 and v15 with Upd 3; WinCC Runtime Professional v14/v15; PCS7 with WinCC updaters). Root cause is an exposed DCOM interface that could let an authenticated, network-reachable attacker execute ...

9CVSS8.6AI score0.01926EPSS
Save
CVE
CVE
added 2018/12/13 4:00 p.m.88 views

CVE-2018-13812

Siemens SIMATIC HMI/WinCC devices are affected by CVE-2018-13812: a directory traversal flaw in the integrated web server that allows an attacker with network access (no authentication, no user interaction) to download arbitrary files from affected panels and runtimes (4"–22" Comfort Panels, Comf...

7.5CVSS7.3AI score0.03572EPSS
Save
CVE
CVE
added 2018/12/13 4:00 p.m.81 views

CVE-2018-13813

Siemens CVE-2018-13813 affects SIMATIC HMI Comfort Panels (4"–22"), Comfort Outdoor Panels (7" & 15"), KTP Mobile Panels (KTP400F, KTP700/700F, KTP900/900F), WinCC Runtime Advanced/Professional, WinCC (TIA Portal), and HMI Classic Devices (all versions) prior to V15 Update 4. The vulnerability is...

8.1CVSS7.6AI score0.01681EPSS
Save
CVE
CVE
added 2019/05/14 7:54 p.m.79 views

CVE-2019-6572

CVE-2019-6572 affects Siemens SIMATIC HMI Comfort Panels (4"–22"), Comfort Outdoor Panels (7"/15"), KTP Mobile Panels, WinCC Runtime Advanced/Professional, WinCC (TIA Portal) and HMI Classic Devices all versions before V15.1 Update 1. The root cause is use of a hardcoded SNMP community string ena...

9.1CVSS8.7AI score0.02721EPSS
Save
CVE
CVE
added 2016/11/15 7:00 p.m.78 views

CVE-2016-7165

CVE-2016-7165 affects Siemens products including Primary Setup Tool, SIMATIC IT Production Suite, SIMATIC NET PC-Software, SIMATIC STEP 7 (TIA Portal) v13/v5.x, SIMATIC WinCC (TIA Portal) Basic/Professional/Runtime, SIMIT, SINEMA components, etc. Root cause: unquoted service paths enabling local ...

6.9CVSS6.9AI score0.00378EPSS
Save
CVE
CVE
added 2018/12/13 4:00 p.m.78 views

CVE-2018-13814

CVE-2018-13814 affects Siemens SIMATIC panels and WinCC components prior to version 14, including HMI Comfort Panels (4"–22"), Comfort Outdoor Panels (7"/15"), KTP Mobile Panels (KTP400F/700/700F/900/900F), WinCC Runtime Advanced/Professional, WinCC (TIA Portal), and HMI Classic Devices. The vuln...

8.8CVSS8.2AI score0.01684EPSS
Save
CVE
CVE
added 2019/05/14 7:54 p.m.75 views

CVE-2019-10917

CVE-2019-10917 is a local-denial-of-service vulnerability affecting Siemens SIMATIC PCS7/WinCC product families (e.g., WinCC (TIA Portal) v13–v15 and WinCC Runtime Professional; PCS7 v8.0–9.0 with WinCC variants). The issue arises when a local attacker loads a project file, triggering a DoS and c...

5.5CVSS5.1AI score0.00265EPSS
Save
CVE
CVE
added 2017/05/11 10:00 a.m.69 views

CVE-2017-6867

CVE-2017-6867 affects Siemens SIMATIC WinCC family (WinCC v7.3 before Update 11, WinCC v7.4 before SP1; WinCC Runtime Professional v13 before SP2, v14 before SP1; WinCC (TIA Portal) Professional v13 before SP2, v14 before SP1). The issue is improper input validation allowing an authenticated remo...

4.9CVSS5.4AI score0.01923EPSS
Save
CVE
CVE
added 2018/08/07 3:00 p.m.66 views

CVE-2018-11453

Siemens SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) are affected by CVE-2018-11453 due to improper default file permissions in the TIA Portal installer. This allows a local attacker with file system access to insert specially crafted files that may prevent startup (Denial-of-Service) or le...

7.8CVSS7.5AI score0.00358EPSS
Save
CVE
CVE
added 2018/08/07 3:00 p.m.62 views

CVE-2018-11454

CVE-2018-11454 affects Siemens SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) across v10–v15 with default installation permissions. The root cause is improper default file permissions (CWE-276) that allow a local attacker with filesystem access to manipulate files that may be transferred to d...

8.6CVSS8.2AI score0.00443EPSS
Save